MCQ
Papers
Previous Year Paper
Exam
Quiz
Tournament
Test Series
Assessment Services
Login/Sign Up
Quiz
Year 2023
November
Week # 3
Expire on 14 Dec 2023
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
November
Week # 4
Expire on 21 Dec 2023
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
December
Week # 1
Expire on 31 Dec 2023
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
December
Week # 2
Expire on 07 Jan 2024
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
FAQs
November
Week # 2 Quiz 1
Q1.
A 3-phase 6-pole 50 Hz induction motor is running at 5% slip, what will be the speed of motor?
850 rpm
950 rpm
900 pm
1000 rpm
Q2.
The inrush current in a transformer at no load is maximum if the supply voltage is switched on
At peak voltage value
At zero voltage value
At half voltage value
At 0.866 times voltage value
Q3.
When the supply voltage to an induction motor is reduced by 10%, the maximum torque will decrease by approximately
5%
10%
20%
40%
Q4.
Statement 1: The reactive power drawn by an induction motor will be same irrespective of load torque. Statement 2: The active power drawn by an induction motor will be same irrespective of load torque. Statement 3: The reactive power drawn by an induction motor varies with the variation of load torque. Statement 4: The active power drawn by an induction motor varies with the variation of load torque. Which of these statements are true?
Statements 1 & 2
Statements 2 & 3
Statements 1 & 4
Statements 2 & 4
Q5.
A single phase transformer when supplied from a 220V, 50Hz supply has eddy current loss of 50 W. If the transformer is connected to a voltage of 330 V, 50 Hz, the Eddy current loss will be
168. 75 w
112. 5 w
75 w
50 W
Q6.
The motor used where high starting torque is required and where the load is subject to heavy fluctuations is a
d.c. series motor
Differential compound motor
d.c. shunt motor
Cumulative compound motor
Q7.
A winding of 4 pole alternator having 36 slots & a coil span of 1 to 8 is short pitched by
20 Degree
80 Degree
140 Degree
40 Degree
Q8.
A 25KW,125V separately excited machine is running at constant speed of 3000 RPM with open circuit terminal voltage of 125V (consider field current as constant).The armature resistance and terminal voltage are 0.02 ohm and 128V respectively. Hence the armature current and terminal power will be
120A ,19.20KW
120A,18.75KW
150A,18.75KW
150A,19.20KW
Q9.
A 10 kVA, 400V/200 V single phase transformer with a resistance of 3 % and reactance of 6 % is supplying a current of 50 A to a resistive load, voltage across load is
176 V
188.7 V
194 V
205.6 V
Q10.
A 4-pole, \(500\: V\) DC shunt motor has 720 wave connected conductor on its armature. The full load armature current is \(60\: A\) and the flux per pole is \(0.03\: Wb\), the armature resistance including brush contact is \(0.2\: \Omega\). Calculate the full load speed of the motor.
433.33 RPM
677.77 RPM
633.33 RPM
567.67 RPM