MCQ
Papers
Previous Year Paper
DDCET 2024 Paper
Exam
Quiz
Tournament
Test Series
Assessment Services
Login/Sign Up
Quiz
Year 2024
April
Week # 4
Expire on 21 May 2024
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
May
Week # 1
Expire on 31 May 2024
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
May
Week # 2
Expire on 07 Jun 2024
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
May
Week # 3
Expire on 14 Jun 2024
Quiz 1
Get Started
Quiz 2
Get Started
Quiz 3
Get Started
Quiz 4
Get Started
Quiz 5
Get Started
FAQs
May
Week # 1 Quiz 5
Q1.
The steady state error in case of a PI controller is always,
Unity
Infinite
Depends on input
Zero
Q2.
Which type of feedback leads to instability in a control system?
Negative feedback
Positive feedback
Regenerative feedback
Degenerative feedback
Q3.
Which of the following statements is true about stability in control systems?
A stable system always converges to a steady-state.
A stable system can have oscillations.
An unstable system is always highly damped.
A stable system cannot have overshoot.
Q4.
Source power is modulated with ............... in a closed loop system.
Reference signal
Error signal
Actuating signal
Feed back signal
Q5.
The ratio of output to input is............at resonance peak.
Highest
Zero
Lowest
None of the Above
Q6.
If GM is Gain Margin, PM is Phase Margin, GCF is Gain Crossover Frequency and PCF is Phase Crossover Frequency, which of the following is correct?
GM corresponds to GCF only
PM corresponds to PCF only
GM corresponds to GCF and PM corresponds to PCF
GM corresponds to PCF and PM corresponds to GCF
Q7.
The stability of the linear system:
Determined by the location of the poles
Dependent entirely on whether the system is driven
The stability of the undriven linear system is dependent on the magnitude of the final initial state.
Stability cannot be determined by the open loop poles
Q8.
Which of the following is a necessary condition for the stability of a control system?
All poles of the transfer function must have negative real parts
All poles of the transfer function must have positive real parts
The system must have only real poles
The system must have both real and complex poles
Q9.
The efficiency of a 400/200 V, 200 kVA singl-phase transformer is 98.5 % at full load at 0.8 lagging power factor. At half load, 0.8 power factor lagging the efficiency is 97.5 %. Calculate the values of core loss and full-load copper loss.
1842 W and 595 W
1887 W and 550 W
1922 W and 515 W
1812 W and 625 W
Q10.
A transformer takes a current of 0.6 A and absorbs 64 W when the primary is connected to its normal supply of 200 V, 50 Hz, the secondary being on open circuit. The iron loss current is
0.2A
0.43 A
1 A
0.32 A
SUBMIT
Record & Track Your Performance
Register With Us