Q11.
A 1 KVA, single phase, 50 Hz, 100/250 V transformer gives the following results on short circuit test conducted at high voltage side:
Voltmeter reading: 12.5 V; Ammeter reading: 4 A; wattmeter readin: 80 W.
The equivalent resistance referred to high voltage side will be _______.
20 ohms
5 ohms
10 ohms
40 ohms
Show Answer
Solution
Q12.
A 3000/300 V transformer takes 0.8 A at power factor of 0.4 on open circuit. Magnetizing current of the transformer will be
0.73 A
0.53 A
0.33 A
0.83 A
Show Answer
Solution
Q13.
Primary and secondary voltage of autotransformer are 500 V and 400 V repectively. When secondary current is 100 A, calculate % saving of copper
70%
80%
75%
78%
Show Answer
Solution
Q14.
Calculate core area of 500 kVA , 1-phase, 50 Hz, 6600/5000 V auto transformer, emf per turn = 8 V, maximum flux density 1.3 Wb/square meter
234 sq cm
337 sq cm
277 sq cm
289 sq cm
Show Answer
Solution
Q15.
In a transformer zero voltage regulation at full load is
not possible
possible at unity p.f.
possible at leading p.f.
possible at lagging p.f.
Show Answer
Solution
Q16.
A transformer has copper loss of 1.5 % and reactance of 3.5 % when tested on load. If its full load regulation is -0.9 % find its power factor.
0.85 lagging
0.8 leading
0.85 leading
0.8 lagging
Show Answer
Solution
Q17.
Transformer will operate at maximum efficiency when
Copper loss = Iron loss
Hysteresis Loss = Eddy current Loss
Eddy current Loss = Copper Loss
Hysteresis Loss = Copper Loss
Show Answer
Solution
Q18.
No load efficiency of transformer is________than full load efficiency
same
lesser
greater
depends on load
Show Answer
Solution
Q19.
Open circuit and short circuit tests on a 3 kVA, 230 / 230 V, 50 Hz, single phase transformer gave the following results:
OC test: 230 V, 2 A, 100 W
SC test: 15 V, 13 A, 120 W
Determine the efficiency of the transformer at full load and 0.80 power factor lagging.
96.60%
91.60%
98.60%
94.60%
Show Answer
Solution
Q20.
A 1000 KVA transformer has an efficiency of 95% at full load and also at 60% of full load, both at unity power factor. Determine the efficiency of the transformer at 80% of full load and unity power factor
92.15%
95.15%
97.15%
93.15%
Show Answer
Solution
Previous Page
1
2
3
4
Next Page
Last ›